ISSU

Unified ISSU

A unified in-service software upgrade (unified ISSU) enables you to upgrade between two different Junos OS releases with no disruption on the control plane and with minimal disruption of traffic. Unified ISSU is supported only on dual Routing Engine platforms. In addition, the graceful Routing Engine switchover (GRES) and nonstop active routing (NSR) must be enabled.
A unified ISSU provides the following benefits:

  • Eliminates network downtime during software image upgrades
  • Reduces operating costs, while delivering higher service levels
  • Allows fast implementation of new features

A unified ISSU has the following caveats:
  • The master Routing Engine and backup Routing Engine must be running the same software version before you can perform a unified ISSU.
  • Graceful Routing Engine switchover (GRES) (check it with show system switchover)and NSR nonstop active routing must be enabled. (note NSR is not supported in all devices.
  • You cannot take any PICs online or offline during a unified ISSU.
  • You can verify the unified ISSU compatibility of the software, hardware, and the configuration on a device by issuing the request system software validate in-service-upgrade command. This command runs the validation checks, and shows whether the operating system, device components, and configurations are ISSU compatible or not. See request system software validate-in-service-upgrade for more information.
  • Unicast RPF-related statistics are not saved across a unified ISSU, and the unicast RPF counters are reset to zero during a unified ISSU.
  • BGP session uptime and downtime statistics are not synchronized between the primary and backup Routing Engines during NSR and ISSU. The backup Routing Engine maintains its own session uptime based on the time when the backup first becomes aware of the established sessions. For example, if the backup Routing Engine is rebooted (or if you run restart routing on the backup Routing Engine), the backup's uptime is a short duration, because the backup has just learned about the established sessions. If the backup is operating when the BGP sessions first come up on the primary, the uptime on the primary and the uptime on the backup are almost the same duration. After a Routing Engine switchover, the new master continues from the time left on the standby Routing Engine.
  • You must disable the unconditional-src-learn statement at the [edit interfaces interface-name unit 0 family inet] hierarchy level before the unified ISSU process begins and enable it after the unified ISSU process is complete. Note that the unconditional-src-learn statement is disabled by default.
  • Starting with Junos OS Release 13.2, unified ISSU is supported on PTX5000 routers with the FPC-PTX-P1-A FPC. However, you can perform unified ISSU only from Junos OS Release 13.2 to 13.3 and from Junos OS Release 14.1 to a later release. You must not perform unified ISSU from Junos OS Release 13.2 or 13.3 to 14.1 and later releases.
  • LACP is not supported during unified ISSU on PTX Series routers. You must disable the lacp statement at the [edit interfaces interface-name aggregated-ether-options] hierarchy level before the unified ISSU process begins and enable it after the unified ISSU process is complete.
After the request system software in-service-upgrade command is issued, the following process occurs.
Note: In the illustrations below, a solid line indicates the high-speed internal link between a Routing Engine and a Packet Forwarding Engine. A dotted line indicates the chassis process (chassisd), another method of communication between a Routing Engine and a Packet Forwarding Engine. RE0m and RE1s indicate master and backup (or standby) Routing Engines, respectively.
Note: The following process pertains to all supported routing platforms except the TX Matrix router and TX Matrix Plus router. For information about the unified ISSU process on the TX Matrix router, see Unified ISSU Process on the TX Matrix Router. For more information about the unified ISSU process on the TX Matrix Plus router, see Unified ISSU Process on the TX Matrix Plus Router and on the TX Matrix Plus Router with 3D SIBs. On most routers, the Packet Forwarding Engine resides on an FPC. However, on an M120 router, the Forwarding Engine Board (FEB) replaces the functions of a Packet Forwarding Engine. In the illustrations and steps, when considering an M120 router, you can regard the PFE as an FPC. As an additional step on an M120 router, after the FPCs and PICs have been upgraded, the FEBs are upgraded.
  1. The master Routing Engine validates the router configuration to ensure that it can be committed when you use the new software version. Checks are made for disk space available for the /var file system on both Routing Engines, for unsupported configurations, and for unsupported Physical Interface Cards (PICs). If there is not sufficient disk space available on either of the Routing Engines, the unified ISSU process fails and returns an error message saying that the Routing Engine does not have enough disk space available. However, unsupported PICs do not prevent a unified ISSU. The software issues a warning to indicate that these PICs will restart during the upgrade. Similarly, an unsupported protocol configuration does not prevent a unified ISSU. The software issues a warning that packet loss may occur for the protocol during the upgrade.
  2. When the validation succeeds, the kernel state synchronization daemon (ksyncd) synchronizes the kernel on the backup Routing Engine with the master Routing Engine.
  3. The backup Routing Engine is upgraded with the new software image. Before being upgraded, the backup Routing Engine gets the configuration file from the master Routing Engine and validates the configuration to ensure that it can be committed using the new software version. After being upgraded, it is resynchronized with the master Routing Engine. In the illustration, an apostrophe ( ' ) indicates that the device is running the new version of software.
  4. The chassis process (chassisd) on the master Routing Engine prepares other software processes for the unified ISSU. When all the processes are ready, chassisd sends an ISSU_PREPARE message to the FPCs installed in the router.
  5. The Packet Forwarding Engine on each FPC saves its state and downloads the new software image from the backup Routing Engine. Next, each Packet Forwarding Engine sends an ISSU_READY message to the chassis process (chassisd).
  6. After receiving an ISSU_READY message from a Packet Forwarding Engine, the chassis process (chassisd) sends an ISSU_REBOOT message to the FPC on which the Packet Forwarding Engine resides. The FPC reboots with the new software image. After the FPC is rebooted, the Packet Forwarding Engine restores the FPC state and a high-speed internal link is established with the backup Routing Engine running the new software. The chassis process (chassisd) is also reestablished with the master Routing Engine.
  7. After all Packet Forwarding Engines have sent a READY message using the chassis process (chassisd) on the master Routing Engine, other software processes are prepared for a Routing Engine switchover. The system is ready for a switchover at this point.
    Note: For M120 routers, the FEBs are upgraded at this point. When all FEBs have been upgraded, the system is ready for a switchover.
  8. The Routing Engine switchover occurs, and the backup Routing Engine becomes the new master Routing Engine.
  9. The new backup Routing Engine is now upgraded to the new software image. (This step is skipped if you have not specified the no-old-master-upgrade option.)
  10. When the backup Routing Engine has been successfully upgraded, the unified ISSU is complete.

 

 

 

Performing a Unified ISSU

You can perform a unified ISSU in one of three ways:
  1. Upgrading and Rebooting Both Routing Engines Automatically
  2. Upgrading Both Routing Engines and Rebooting the New Backup Routing Engine Manually
  3. Upgrading and Rebooting Only One Routing Engine

Upgrading and Rebooting Both Routing Engines Automatically

When you issue the request system software in-service-upgrade command with the reboot option, the system automatically upgrades both Routing Engines to the newer software and reboots both Routing Engines. This option enables you to complete the unified ISSU with a single command.
To perform a unified ISSU using the request system software in-service-upgrade package-name reboot command, complete the following steps:
  1. Download the software package from the Juniper Networks Support website, http://www.juniper.net/support/. Choose the Canada and U.S., Worldwide, or Junos-FIPS edition. Place the package on a local server. To download the package, you must have a service contract and an access account. If you do not have an access account, complete the registration form at the Juniper Networks website: https://www.juniper.net/registration/Register.jsp.
  2. Copy the package to the router. We recommend that you copy it to the /var/tmp directory, which is a large file system on the hard disk.
    user@host>file copy ftp://username:prompt@ftp.hostname.net/filename/var/tmp/filename
  3. To verify the current software version running on both Routing Engines, on the master Routing Engine issue the show version invoke-on all-routing-engines command. The following example shows that both Routing Engines are running an image of Junos OS, Release 9.0, that was built on December 11, 2007:
    {backup}
    user@host> show version invoke-on all-routing-engines
    re0:
    --------------------------------------------------------------------------
    Hostname: host
    Model: m320
    JUNOS Base OS boot [9.0-20071211.2]
    JUNOS Base OS Software Suite 9.0-20071211.2]
    JUNOS Kernel Software Suite [9.0-20071211.2]
    JUNOS Crypto Software Suite [9.0-20071211.2]
    JUNOS Packet Forwarding Engine Support (M/T Common) [9.0-20071211.2]
    JUNOS Packet Forwarding Engine Support (M320) [9.0-20071211.2]
    JUNOS Online Documentation [9.0-20071211.2]
    JUNOS Routing Software Suite [9.0-20071211.2]
    
    re1:
    --------------------------------------------------------------------------
    Hostname: host1
    Model: m320
    JUNOS Base OS boot [9.0-20071211.2]
    JUNOS Base OS Software Suite [9.0-20071211.2]
    JUNOS Kernel Software Suite [9.0-20071211.20]
    JUNOS Crypto Software Suite [9.0-20071211.2]
    JUNOS Packet Forwarding Engine Support (M/T Common) [9.0-20071211.2]
    JUNOS Packet Forwarding Engine Support (M320) [9.0-20071211.2]
    JUNOS Online Documentation [9.0-20071211.2]
    JUNOS Routing Software Suite [9.0-20071211.2]
    
  4. On the master Routing Engine, issue the request system software in-service-upgrade package-name reboot command. The following example upgrades the current version to an image of Junos OS, Release 9.0, that was built on January 14, 2008:
    {master}
    user@host> request system software in-service-upgrade /var/tmp/jinstall-9.0-20080114.2-domestic-signed.tgz reboot
    ISSU: Validating Image
    PIC 0/3 will be offlined (In-Service-Upgrade not supported)
    Do you want to continue with these actions being taken ? [yes,no] (no) yes 
    
    ISSU: Preparing Backup RE
    Pushing bundle to re1
    Checking compatibility with configuration
    Initializing...
    Using jbase-9.0-20080114.2
    Verified manifest signed by PackageProduction_9_0_0
    Using /var/tmp/jinstall-9.0-20080114.2-domestic-signed.tgz
    Verified jinstall-9.0-20080114.2-domestic.tgz signed by PackageProduction_9_0_0
    Using jinstall-9.0-20080114.2-domestic.tgz
    Using jbundle-9.0-20080114.2-domestic.tgz
    Checking jbundle requirements on /
    Using jbase-9.0-20080114.2.tgz
    Verified manifest signed by PackageProduction_9_0_0
    Using jkernel-9.0-20080114.2.tgz
    Verified manifest signed by PackageProduction_9_0_0
    Using jcrypto-9.0-20080114.2.tgz
    Verified manifest signed by PackageProduction_9_0_0
    Using jpfe-9.0-20080114.2.tgz
    Using jdocs-9.0-20080114.2.tgz
    Verified manifest signed by PackageProduction_9_0_0
    Using jroute-9.0-20080114.2.tgz
    Verified manifest signed by PackageProduction_9_0_0
    Hardware Database regeneration succeeded
    Validating against /config/juniper.conf.gz
    mgd: commit complete
    Validation succeeded
    Installing package '/var/tmp/jinstall-9.0-20080114.2-domestic-signed.tgz' ...
    Verified jinstall-9.0-20080114.2-domestic.tgz signed by PackageProduction_9_0_0
    Adding jinstall...
    Verified manifest signed by PackageProduction_9_0_0
    
    WARNING:     This package will load JUNOS 9.0-20080114.2 software.
    WARNING:     It will save JUNOS configuration files, and SSH keys
    WARNING:     (if configured), but erase all other files and information
    WARNING:     stored on this machine.  It will attempt to preserve dumps
    WARNING:     and log files, but this can not be guaranteed.  This is the
    WARNING:     pre-installation stage and all the software is loaded when
    WARNING:     you reboot the system.
    
    Saving the config files ...
    NOTICE: uncommitted changes have been saved in /var/db/config/juniper.conf.pre-install
    Installing the bootstrap installer ...
    
    WARNING:     A REBOOT IS REQUIRED TO LOAD THIS SOFTWARE CORRECTLY. Use the
    WARNING:     'request system reboot' command when software installation is
    WARNING:     complete. To abort the installation, do not reboot your system,
    WARNING:     instead use the 'request system software delete jinstall'
    WARNING:     command as soon as this operation completes.
    
    Saving package file in /var/sw/pkg/jinstall-9.0-20080114.2-domestic-signed.tgz ...
    Saving state for rollback ...
    Backup upgrade done
    Rebooting Backup RE
    
    Rebooting re1
    ISSU: Backup RE Prepare Done
    Waiting for Backup RE reboot
    GRES operational
    Initiating Chassis In-Service-Upgrade
    Chassis ISSU started
    ISSU: Backup RE Prepare Done
    ISSU: Preparing Daemons
    ISSU: Daemons Ready for ISSU
    ISSU: Starting Upgrade for FRUs
    ISSU: Preparing for Switchover
    ISSU: Ready for Switchover
    Checking In-Service-Upgrade status
      Item           Status                  Reason
      FPC 0          Online (ISSU)        
      FPC 1          Online (ISSU)        
      FPC 2          Online (ISSU)        
      FPC 6          Online (ISSU)        
      FPC 7          Online (ISSU)        
    Resolving mastership...
    Complete. The other routing engine becomes the master.
    ISSU: RE switchover Done
    ISSU: Upgrading Old Master RE
    Installing package '/var/tmp/paKEuy' ...
    Verified jinstall-9.0-20080114.2-domestic.tgz signed by PackageProduction_9_0_0
    Adding jinstall...
    Verified manifest signed by PackageProduction_9_0_0
    
    WARNING:     This package will load JUNOS 9.0-20080114.2 software.
    WARNING:     It will save JUNOS configuration files, and SSH keys
    WARNING:     (if configured), but erase all other files and information
    WARNING:     stored on this machine.  It will attempt to preserve dumps
    WARNING:     and log files, but this can not be guaranteed.  This is the
    WARNING:     pre-installation stage and all the software is loaded when
    WARNING:     you reboot the system.
    
    Saving the config files ...
    NOTICE: uncommitted changes have been saved in /var/db/config/juniper.conf.pre-install
    Installing the bootstrap installer ...
    
    WARNING:     A REBOOT IS REQUIRED TO LOAD THIS SOFTWARE CORRECTLY. Use the
    WARNING:     'request system reboot' command when software installation is
    WARNING:     complete. To abort the installation, do not reboot your system,
    WARNING:     instead use the 'request system software delete jinstall'
    WARNING:     command as soon as this operation completes.
    
    Saving package file in /var/sw/pkg/jinstall-9.0-20080114.2-domestic-signed.tgz ...
    cp: /var/tmp/paKEuy is a directory (not copied).
    Saving state for rollback ...
    ISSU: Old Master Upgrade Done
    ISSU: IDLE
    Shutdown NOW!
    Reboot consistency check bypassed - jinstall 9.0-20080114.2 will complete installation upon reboot
    [pid 30227]
    
    *** FINAL System shutdown message from root@host ***
    
    System going down IMMEDIATELY
                                                                                   
    Connection to host closed.
    When the new backup (old master) Routing Engine is rebooted, you are logged out from the router.
  5. After waiting a few minutes, log in to the router again. You are logged in to the new backup Routing Engine (re0). To verify that both Routing Engines have been upgraded, issue the following command:
    {backup}
    user@host> show version invoke-on all-routing-engines
    re0:
    --------------------------------------------------------------------------
    Hostname: host
    Model: m320
    JUNOS Base OS boot [9.0-20080114.2]
    JUNOS Base OS Software Suite 9.0-20080114.2]
    JUNOS Kernel Software Suite [9.0-20080114.2]
    JUNOS Crypto Software Suite [9.0-20080114.2]
    JUNOS Packet Forwarding Engine Support (M/T Common) [9.0-20080114.2]
    JUNOS Packet Forwarding Engine Support (M320) [9.0-20080114.2]
    JUNOS Online Documentation [9.0-20080114.2]
    JUNOS Routing Software Suite [9.0-20080114.2]
    
    re1:
    --------------------------------------------------------------------------
    Hostname: host1
    Model: m320
    JUNOS Base OS boot [9.0-20080114.2]
    JUNOS Base OS Software Suite [9.0-20080114.2]
    JUNOS Kernel Software Suite [9.0-20080114.2]
    JUNOS Crypto Software Suite [9.0-20080114.2]
    JUNOS Packet Forwarding Engine Support (M/T Common) [9.0-20080114.2]
    JUNOS Packet Forwarding Engine Support (M320) [9.0-20080114.2]
    JUNOS Online Documentation [9.0-20080114.2]
    JUNOS Routing Software Suite [9.0-20080114.2]
    
  6. To make re0 the master Routing Engine, issue the following command:
    {backup}
    user@host> request chassis routing-engine master acquire
    Attempt to become the master routing engine ? [yes,no] (no) yes 
    
    Resolving mastership...
    Complete. The local routing engine becomes the master.
    
    {master}
    user@host> 
     
    if for any reason ISSU procedure stops progressing complete 
    open a new session on the master ROuting Engine and Issue the request system
     software abort in-service-upgrade command
     
  7. Issue the request system snapshot command on each Routing Engine to back up the system software to the router’s hard disk.
    Note: The root file system is backed up to /altroot, and /config is backed up to /altconfig. After you issue the request system snapshot command, the router’s flash and hard disks are identical. You can return to the previous version of the software only by booting the router from removable media.

Upgrading Both Routing Engines and Rebooting the New Backup Routing Engine Manually

When you issue the request system software in-service-upgrade command without any options, the system upgrades and reboots the new master Routing Engine to the newer software. The new software is placed on the new backup (old master) Routing Engine; however, to complete the upgrade, you must issue the request system reboot command on the new backup Routing Engine.
To perform a unified ISSU using the request system software in-service-upgrade package-name command without any options, complete the following steps:
  1. Download the software package from the Juniper Networks Support website, http://www.juniper.net/support/. Choose the Canada and U.S., Worldwide, or Junos-FIPS edition. Place the package on a local server. To download the package, you must have a service contract and an access account. If you do not have an access account, complete the registration form at the Juniper Networks website: https://www.juniper.net/registration/Register.jsp.
  2. Copy the package to the router. We recommend that you copy it to the /var/tmp directory, which is a large file system on the hard disk.
    user@host>file copy ftp://username:prompt@ftp.hostname.net/filename/var/tmp/filename
  3. To verify the current software version running on both Routing Engines, on the master Routing Engine, issue the show version invoke-on all-routing-engines command. The following example shows that both Routing Engines are running Junos OS Release 9.0R1:
    {master}
    user@host> show version invoke-on all-routing-engines
    re0:
    --------------------------------------------------------------------------
    Hostname: host
    Model: m320
    JUNOS Base OS boot [9.0R1]
    JUNOS Base OS Software Suite [9.0R1]
    JUNOS Kernel Software Suite [9.0R1]
    JUNOS Crypto Software Suite [9.0R1]
    JUNOS Packet Forwarding Engine Support (M/T Common) [9.0R1]
    JUNOS Packet Forwarding Engine Support (M320) [9.0R1]
    JUNOS Online Documentation [9.0R1]
    JUNOS Routing Software Suite [9.0R1]
    
    re1:
    --------------------------------------------------------------------------
    Hostname: host1
    Model: m320
    JUNOS Base OS boot [9.0R1]
    JUNOS Base OS Software Suite [9.0R1]
    JUNOS Kernel Software Suite [9.0R1]
    JUNOS Crypto Software Suite [9.0R1]
    JUNOS Packet Forwarding Engine Support (M/T Common) [9.0R1]
    JUNOS Packet Forwarding Engine Support (M320) [9.0R1]
    JUNOS Online Documentation [9.0R1]
    JUNOS Routing Software Suite [9.0R1]
  4. On the master Routing Engine, issue the request system software in-service-upgrade package-name command. The following example upgrades the current version to Junos OS Release 9.0R1.2:
    user@host> request system software in-service-upgrade /var/tmp/jinstall-9.0R1.2-domestic-signed.tgz
    ISSU: Validating Image
    FPC 4 will be offlined (In-Service-Upgrade not supported)
    Do you want to continue with these actions being taken ? [yes,no] (no) yes 
    
    ISSU: Preparing Backup RE
    Pushing bundle to re1
    Checking compatibility with configuration
    Initializing...
    Using jbase-9.0-20080117.0
    Verified manifest signed by PackageProduction_9_0_0
    Using /var/tmp/jinstall-9.0R1.2-domestic-signed.tgz
    Verified jinstall-9.0R1.2-domestic.tgz signed by PackageProduction_9_0_0
    Using jinstall-9.0R1.2-domestic.tgz
    Using jbundle-9.0R1.2-domestic.tgz
    Checking jbundle requirements on /
    Using jbase-9.0R1.2.tgz
    Verified manifest signed by PackageProduction_9_0_0
    Using jkernel-9.0R1.2.tgz
    Verified manifest signed by PackageProduction_9_0_0
    Using jcrypto-9.0R1.2.tgz
    Verified manifest signed by PackageProduction_9_0_0
    Using jpfe-9.0R1.2.tgz
    Using jdocs-9.0R1.2.tgz
    Verified manifest signed by PackageProduction_9_0_0
    Using jroute-9.0R1.2.tgz
    Verified manifest signed by PackageProduction_9_0_0
    Hardware Database regeneration succeeded
    Validating against /config/juniper.conf.gz
    mgd: commit complete
    Validation succeeded
    Installing package '/var/tmp/jinstall-9.0R1.2-domestic-signed.tgz' ...
    Verified jinstall-9.0R1.2-domestic.tgz signed by PackageProduction_9_0_0
    Adding jinstall...
    Verified manifest signed by PackageProduction_9_0_0
    
    WARNING:     This package will load JUNOS 9.0R1.2 software.
    WARNING:     It will save JUNOS configuration files, and SSH keys
    WARNING:     (if configured), but erase all other files and information
    WARNING:     stored on this machine.  It will attempt to preserve dumps
    WARNING:     and log files, but this can not be guaranteed.  This is the
    WARNING:     pre-installation stage and all the software is loaded when
    WARNING:     you reboot the system.
    
    Saving the config files ...
    NOTICE: uncommitted changes have been saved in /var/db/config/juniper.conf.pre-install
    Installing the bootstrap installer ...
    
    WARNING:     A REBOOT IS REQUIRED TO LOAD THIS SOFTWARE CORRECTLY. Use the
    WARNING:     'request system reboot' command when software installation is
    WARNING:     complete. To abort the installation, do not reboot your system,
    WARNING:     instead use the 'request system software delete jinstall'
    WARNING:     command as soon as this operation completes.
    
    Saving package file in /var/sw/pkg/jinstall-9.0R1.2-domestic-signed.tgz ...
    Saving state for rollback ...
    Backup upgrade done
    Rebooting Backup RE
    
    Rebooting re1
    ISSU: Backup RE Prepare Done
    Waiting for Backup RE reboot
    GRES operational
    Initiating Chassis In-Service-Upgrade
    Chassis ISSU started
    ISSU: Backup RE Prepare Done
    ISSU: Preparing Daemons
    ISSU: Daemons Ready for ISSU
    ISSU: Starting Upgrade for FRUs
    ISSU: Preparing for Switchover
    ISSU: Ready for Switchover
    Checking In-Service-Upgrade status
      Item           Status                  Reason
      FPC 0          Online (ISSU)        
      FPC 1          Online (ISSU)        
      FPC 2          Online (ISSU)        
      FPC 3          Online (ISSU)        
      FPC 4          Offline                 Offlined by cli command
      FPC 5          Online (ISSU)        
    Resolving mastership...
    Complete. The other routing engine becomes the master.
    ISSU: RE switchover Done
    ISSU: Upgrading Old Master RE
    Installing package '/var/tmp/paeBi5' ...
    Verified jinstall-9.0R1.2-domestic.tgz signed by PackageProduction_9_0_0
    Adding jinstall...
    Verified manifest signed by PackageProduction_9_0_0
    
    WARNING:     This package will load JUNOS 9.0R1.2 software.
    WARNING:     It will save JUNOS configuration files, and SSH keys
    WARNING:     (if configured), but erase all other files and information
    WARNING:     stored on this machine.  It will attempt to preserve dumps
    WARNING:     and log files, but this can not be guaranteed.  This is the
    WARNING:     pre-installation stage and all the software is loaded when
    WARNING:     you reboot the system.
    
    Saving the config files ...
    NOTICE: uncommitted changes have been saved in /var/db/config/juniper.conf.pre-install
    Installing the bootstrap installer ...
    
    WARNING:     A REBOOT IS REQUIRED TO LOAD THIS SOFTWARE CORRECTLY. Use the
    WARNING:     'request system reboot' command when software installation is
    WARNING:     complete. To abort the installation, do not reboot your system,
    WARNING:     instead use the 'request system software delete jinstall'
    WARNING:     command as soon as this operation completes.
    
    Saving package file in /var/sw/pkg/jinstall-9.0R1.2-domestic-signed.tgz ...
    cp: /var/tmp/paeBi5 is a directory (not copied).
    Saving state for rollback ...
    ISSU: Old Master Upgrade Done
    ISSU: IDLE
  5. Issue the show version invoke-on all-routing-engines command to verify that the new backup (old master) Routing Engine (re0), is still running the previous software image, while the new master Routing Engine (re1) is running the new software image:
    {backup}
    user@host> show version
    re0:
    --------------------------------------------------------------------------
    Hostname: user
    Model: m320
    JUNOS Base OS boot [9.0R1]
    JUNOS Base OS Software Suite [9.0R1]
    JUNOS Kernel Software Suite [9.0R1]
    JUNOS Crypto Software Suite [9.0R1]
    JUNOS Packet Forwarding Engine Support (M/T Common) [9.0R1]
    JUNOS Packet Forwarding Engine Support (M320) [9.0R1]
    JUNOS Online Documentation [9.0R1]
    JUNOS Routing Software Suite [9.0R1]
    labpkg [7.0]
    JUNOS Installation Software [9.0R1.2]
    
    re1:
    --------------------------------------------------------------------------
    Hostname: user1
    Model: m320
    JUNOS Base OS boot [9.0R1.2]
    JUNOS Base OS Software Suite [9.0R1.2]
    JUNOS Kernel Software Suite [9.0R1.2]
    JUNOS Crypto Software Suite [9.0R1.2]
    JUNOS Packet Forwarding Engine Support (M/T Common) [9.0R1.2]
    JUNOS Packet Forwarding Engine Support (M320) [9.0R1.2]
    JUNOS Online Documentation [9.0R1.2]
    JUNOS Routing Software Suite [9.0R1.2]
  6. At this point, if you choose not to install the newer software version on the new backup Routing Engine (re1), you can issue the request system software delete jinstall command on it. Otherwise, to complete the upgrade, go to the next step.
  7. Reboot the new backup Routing Engine (re0) by issuing the request system reboot command:
    {backup}
    user@host> request system reboot
    Reboot the system ? [yes,no] (no) yes 
    
    Shutdown NOW!
    Reboot consistency check bypassed - jinstall 9.0R1.2 will complete installation upon reboot
    [pid 6170]
    
    {backup}
    user@host>
    System going down IMMEDIATELY
                                                                                   
    Connection to host closed by remote host.
    Connection to host closed.
    If you are not on the console port, you are disconnected from the router session.
  8. After waiting a few minutes, log in to the router again. You are logged in to the new backup Routing Engine (re0). To verify that both Routing Engines have been upgraded, issue the following command:
    {backup}
    user@host> show version invoke-on all-routing-engines
    re0:
    --------------------------------------------------------------------------
    Hostname: host
    Model: m320
    JUNOS Base OS boot [9.0R1.2]
    JUNOS Base OS Software Suite [9.0R1.2]
    JUNOS Kernel Software Suite [9.0R1.2]
    JUNOS Crypto Software Suite [9.0R1.2]
    JUNOS Packet Forwarding Engine Support (M/T Common) [9.0R1.2]
    JUNOS Packet Forwarding Engine Support (M320) [9.0R1.2]
    JUNOS Online Documentation [9.0R1.2]
    JUNOS Routing Software Suite [9.0R1.2]
    
    re1:
    --------------------------------------------------------------------------
    Hostname: host1
    Model: m320
    JUNOS Base OS boot [9.0R1.2]
    JUNOS Base OS Software Suite [9.0R1.2]
    JUNOS Kernel Software Suite [9.0R1.2]
    JUNOS Crypto Software Suite [9.0R1.2]
    JUNOS Packet Forwarding Engine Support (M/T Common) [9.0R1.2]
    JUNOS Packet Forwarding Engine Support (M320) [9.0R1.2]
    JUNOS Online Documentation [9.0R1.2]
    JUNOS Routing Software Suite [9.0R1.2]
    
  9. To make re0 the master Routing Engine, issue the following command:
    {backup}
    user@host> request chassis routing-engine master acquire
    Attempt to become the master routing engine ? [yes,no] (no) yes 
    
    Resolving mastership...
    Complete. The local routing engine becomes the master.
    
    {master}
    user@host> 
  10. Issue the request system snapshot command on each Routing Engine to back up the system software to the router’s hard disk.
    Note: The root file system is backed up to /altroot, and /config is backed up to /altconfig. After you issue the request system snapshot command, the router’s flash and hard disks are identical. You can return to the previous version of the software only by booting the router from removable media.

Upgrading and Rebooting Only One Routing Engine

When you issue the request system software in-service-upgrade command with the no-old-master-upgrade option, the system upgrades and reboots only the new master Routing Engine. To upgrade the new backup (former master) Routing Engine, you must issue the request system software add command.
To perform a unified ISSU using the request system software in-service-upgrade package-name no-old-master-upgrade commands, complete the following steps:
  1. Download the software package from the Juniper Networks Support website, http://www.juniper.net/support/. Choose the Canada and U.S., Worldwide, or Junos-FIPS edition. Place the package on a local server. To download the package, you must have a service contract and an access account. If you do not have an access account, complete the registration form at the Juniper Networks website: https://www.juniper.net/registration/Register.jsp.
  2. Copy the package to the router. We recommend that you copy it to the /var/tmp directory, which is a large file system on the hard disk.
    user@host>file copy ftp://username:prompt@ftp.hostname.net/filename/var/tmp/filename
  3. To verify the current software version running on both Routing Engines, on the master Routing Engine issue the show version invoke-on all-routing-engines command. The following example shows that both Routing Engines are running an image of Junos OS Release 9.0 that was built on December 11, 2007:
    {backup}
    user@host> show version invoke-on all-routing-engines
    re0:
    --------------------------------------------------------------------------
    Hostname: host
    Model: m320
    JUNOS Base OS boot [9.0-20071211.2]
    JUNOS Base OS Software Suite 9.0-20071211.2]
    JUNOS Kernel Software Suite [9.0-20071211.2]
    JUNOS Crypto Software Suite [9.0-20071211.2]
    JUNOS Packet Forwarding Engine Support (M/T Common) [9.0-20071211.2]
    JUNOS Packet Forwarding Engine Support (M320) [9.0-20071211.2]
    JUNOS Online Documentation [9.0-20071211.2]
    JUNOS Routing Software Suite [9.0-20071211.2]
    
    re1:
    --------------------------------------------------------------------------
    Hostname: host1
    Model: m320
    JUNOS Base OS boot [9.0-20071211.2]
    JUNOS Base OS Software Suite [9.0-20071211.2]
    JUNOS Kernel Software Suite [9.0-20071211.20]
    JUNOS Crypto Software Suite [9.0-20071211.2]
    JUNOS Packet Forwarding Engine Support (M/T Common) [9.0-20071211.2]
    JUNOS Packet Forwarding Engine Support (M320) [9.0-20071211.2]
    JUNOS Online Documentation [9.0-20071211.2]
    JUNOS Routing Software Suite [9.0-20071211.2]
    
  4. On the master Routing Engine, issue the request system software in-service-upgrade package-name no-old-master-upgrade command. The following example upgrades the current version to an image of Junos OS Release 9.0 that was built on January 16, 2008:
    {master}
    user@host> request system software in-service-upgrade /var/tmp/jinstall-9.0-20080116.2-domestic-signed.tgz no-old-master-upgrade
    ISSU: Validating Image
    ISSU: Preparing Backup RE
    Pushing bundle to re1
    Checking compatibility with configuration
    Initializing...
    Using jbase-9.0-20080116.2
    Verified manifest signed by PackageProduction_9_0_0
    Using /var/tmp/jinstall-9.0-20080116.2-domestic-signed.tgz
    Verified jinstall-9.0-20080116.2-domestic.tgz signed by PackageProduction_9_0_0
    Using jinstall-9.0-20080116.2-domestic.tgz
    Using jbundle-9.0-20080116.2-domestic.tgz
    Checking jbundle requirements on /
    Using jbase-9.0-20080116.2.tgz
    Verified manifest signed by PackageProduction_9_0_0
    Using jkernel-9.0-20080116.2.tgz
    Verified manifest signed by PackageProduction_9_0_0
    Using jcrypto-9.0-20080116.2.tgz
    Verified manifest signed by PackageProduction_9_0_0
    Using jpfe-9.0-20080116.2.tgz
    Using jdocs-9.0-20080116.2.tgz
    Verified manifest signed by PackageProduction_9_0_0
    Using jroute-9.0-20080116.2.tgz
    Verified manifest signed by PackageProduction_9_0_0
    Hardware Database regeneration succeeded
    Validating against /config/juniper.conf.gz
    mgd: commit complete
    Validation succeeded
    Installing package '/var/tmp/jinstall-9.0-20080116.2-domestic-signed.tgz' ...
    Verified jinstall-9.0-20080116.2-domestic.tgz signed by PackageProduction_9_0_0
    Adding jinstall...
    Verified manifest signed by PackageProduction_9_0_0
    
    WARNING:     This package will load JUNOS 9.0-20080116.2 software.
    WARNING:     It will save JUNOS configuration files, and SSH keys
    WARNING:     (if configured), but erase all other files and information
    WARNING:     stored on this machine.  It will attempt to preserve dumps
    WARNING:     and log files, but this can not be guaranteed.  This is the
    WARNING:     pre-installation stage and all the software is loaded when
    WARNING:     you reboot the system.
    
    Saving the config files ...
    NOTICE: uncommitted changes have been saved in /var/db/config/juniper.conf.pre-install
    Installing the bootstrap installer ...
    
    WARNING:     A REBOOT IS REQUIRED TO LOAD THIS SOFTWARE CORRECTLY. Use the
    WARNING:     'request system reboot' command when software installation is
    WARNING:     complete. To abort the installation, do not reboot your system,
    WARNING:     instead use the 'request system software delete jinstall'
    WARNING:     command as soon as this operation completes.
    
    Saving package file in /var/sw/pkg/jinstall-9.0-20080116.2-domestic-signed.tgz ...
    Saving state for rollback ...
    Backup upgrade done
    Rebooting Backup RE
    
    Rebooting re1
    ISSU: Backup RE Prepare Done
    Waiting for Backup RE reboot
    GRES operational
    Initiating Chassis In-Service-Upgrade
    Chassis ISSU started
    ISSU: Backup RE Prepare Done
    ISSU: Preparing Daemons
    ISSU: Daemons Ready for ISSU
    ISSU: Starting Upgrade for FRUs
    ISSU: Preparing for Switchover
    ISSU: Ready for Switchover
    Checking In-Service-Upgrade status
      Item           Status                  Reason
      FPC 0          Online (ISSU)        
      FPC 1          Online (ISSU)        
      FPC 2          Online (ISSU)        
      FPC 3          Online (ISSU)        
      FPC 5          Online (ISSU)        
    Resolving mastership...
    Complete. The other routing engine becomes the master.
    ISSU: RE switchover Done
    Skipping Old Master Upgrade
    ISSU: IDLE
    
    {backup}
    user@host>
  5. You are now logged in to the new backup (old master Routing Engine). If you want to install the new software version on the new backup Routing Engine, issue the request system software add /var/tmp/jinstall-9.0-20080116.2-domestic-signed.tgz command.

Thursday, 9 July 2015

syslog sending messages to the console

sending messages to the console

root@vSRX_R2# show
user * {
    any emergency;
}
file messages {
    any any;
    authorization info;
}
file interactive-commands {
    interactive-commands any;
}

[edit system syslog]
root@vSRX_R2#



root@vSRX_R2# set system syslog console any any

[edit]
root@vSRX_R2# commit
commit complete

[edit]
root@vSRX_R2# Jul 10 01:26:35  vSRX_R2 mgd[1268]: UI_COMMIT_PROGRESS: Commit operation in progress: signaling 'Event processing process', pid 948, signal 1, status 0 with notification errors enabled
Jul 10 01:26:35  vSRX_R2 mgd[1268]: UI_COMMIT_PROGRESS: Commit operation in progress: ssync begins
Jul 10 01:26:35  vSRX_R2 mgd[1268]: UI_COMMIT_PROGRESS: Commit operation in progress: ssync ends
Jul 10 01:26:35  vSRX_R2 mgd[1268]: UI_COMMIT_PROGRESS: Commit operation in progress: commit complete
Jul 10 01:26:35  vSRX_R2 mgd[1268]: UI_COMMIT_PROGRESS: Commit operation in progress: signaling 'Alarm control process', pid 1149, signal 30, status 0 with notification errors enabled


[edit]
root@vSRX_R2#

[edit]
root@vSRX_R2#

[edit]
root@vSRX_R2# del system syslog console any any
Jul 10 01:26:48  vSRX_R2 mgd[1268]: UI_CMDLINE_READ_LINE: User 'root', command 'del system syslog console any any '
Jul 10 01:26:48  vSRX_R2 mgd[1268]: UI_CFG_AUDIT_OTHER: User 'root' delete: [system syslog console any] "any

[edit]
root@vSRX_R2# commit
Jul 10 01:26:51  vSRX_R2 mgd[1268]: UI_CMDLINE_READ_LINE: User 'root', command 'commit ' vSRX_R2 mgd[1268]: UI_COMMIT_PROGRESS: Commit operation in progress: activating '/var/etc/rc.conf.inc'
.............................
Jul 10 01:26:56  vSRX_R2 mgd[1268]: UI_COMMIT_PROGRESS: Commit operation in progress: ssync ends
Jul 10 01:26:56  vSRX_R2 mgd[1268]: UI_COMMIT_PROGRESS: Commit operation in progress: notifying daemons of new configuration
Jul 10 01:26:57  vSRX_R2 mgd[1268]: UI_COMMIT_PROGRESS: Commit operation in progress:  notifying eventd(87)
commit complete

[edit]
root@vSRX_R2#